UP-CONVERTER VM-29547030
    UP-converter is intended for signal up-converting. It is used in communication and navigation systems.
    Environmental conditions:
    - temperature range: from 0°C up to + 40°C;
    - air lowered pressure: 4х104 Pа.
    The up-converter restores the operation after being at 213…333 K (minus 60…+70°C) ambient temperatures and at 1.2х104 Pа (90 mm Hg) air decreased pressure.
SPECIFICATION
| Operating input frequency, GHz | 29,8 |
| Input power, dBm | 14 |
| LO frequency range, GHz | 5,4 ±0,12 |
| LO power, dBm | 10 |
| Output frequency range, GHz | 35,2±0,12 |
| Output power, dBm | 3 |
| Operating temperature range, °С | 0...+40 |
| Input/Output | waveguide WR-28 |
| LO input | coaxial SMA type: with M and 1/4 |
| Dimensions, mm | 40х32,5х19,1 |
| Weight, g | 65 |
|