IF AMPLIFIER KRUB.468714.038
      IF amplifier is intended for using in receivers of analog or digital radiorelay station with 70MHz IF. The functions of IF amplifier are the following:
      - regulation of IF signal amplification in automatic gain control regime or in hand control regime;
      - forming of the amplitude frequency response and the phase frequency response of receiving path;
      - forming of the substitute 70 MHz signal in case of input signal decreasing lower then threshold level;
      - forming of the supervisory signals: "IF level", "IF alarm", "Usource control";
      - receiving and executing of the remote control signals: "AGC off", "Hand gain control", "Output power level setting".
      There are 3 models of IF amplifier which differs of the frequency band:
      - KRUB.468714.038 - 30 MHz bandpass;
      - KRUB.468714.038-01 - 18 MHz bandpass;
      - KRUB.468714.038-02 - 7 MHz bandpass.
      Operating conditions of IF amplifiers are the following:
      - ambient temperature: from minus 40 °С up to +55 °С;
      - relative humidity: no more 95% at 35 °С;
      - low pressure: up to 460 mm Hg.
SPECIFICATION
| Operating frequency range at minus 3dB level, MHz, no more | KRUB. 468714.038-00 | KRUB. 468714.038-01 | KRUB. 468714.038-02 |
| - | 30 | 18 | 7 |
| Maximal gain, dB, no less | 60 | 65 | 65 |
| Gain ripple in 70±12 MHz frequency range, dB, no more | 0,4 | not specified |
| Group delay time ripple in 70±12 MHz frequency range, nsec, no more | 4 | not specified |
Output power in AGC regime, mW       normal regime       forced regime | 1±0,25 3,5±0,5 |
| Maximal permissible level of input signal, mW, no more | 1 |
| Automatic gain control level, dB, no less | 55 |
| Noise figure, dB, no more | 5 |
Selectivity       at ±25 MHz, dB, no less       at ±14 MHz, dB, no less       at ±7MHz, dB, no less |
30 |
26 |
20 |
(2-d…4-th) harmonic suppression of output signal       at Pout=1mW, dB       at Pout=3.5mW, dB, no less | 30 20 |
| 3rd intermodulation distortion in full AGC range, dB, no more | 30 |
| input* VSWR, no more. | 1,35 |
| outputs** VSWR, no more. | 1,06 |
Input signal threshold level       of auxiliary generator switching on, dBm       of auxiliary generator switching , dBm | -65 -60 | -70 -65 | -75 -70 |
| Output frequency of auxiliary generator, MHz | 70±0,1 |
| Output power of auxiliary generator, mW | 0,3...1,4 |
“IF level” control voltage, V       Рin=-55 dBm       Рin=-30 dBm       Рin=-10 dBm | 10,5±0,5 6±1 2±1 |
Supply voltage, V       no less       no more | 14,5 18 |
| Consumption current, mA, no more | 120 |
| Dimensions, mm | 188х95х27 |
| Weight, g | 600 |
|