HIGHLY SENSITIVE MODULATION RADIOMETRIC RECEIVER 3 ÌÌ WAVE-LENGTH RANGE
     FUNCTION
- passive location;
- distance temperature measurement;
- radioviewing;
- materials attenuation features measurement.
     CONSTRUCTION CHARACTERISTICS
- internal noising module;
- automatic compensation of the temperature drift with the constant component of the output
signal;
- self-calibration opportunity;
- high linearity of the output characteristic.

SPECIFICATIONS
| Operating frequency range, GHz | 92…96 |
| Modulation frequency, êHz | 2 |
ÔFluctuation sensitivity, Ê/vHz: - with LNA at the output - without LNA at the output
| 0,01 0,03 |
| Supply voltage 50 Hz, V | 220±5 |
|